Name: Control Value, Attribute Set Index
Definition:
A value that may be used by an Expression to specify the Index field
value of the affected Attribute Set Index object.
AC: XASI
Recommended Data Type: SE_UINT16
Possible Enumerators: None
Recommended Maximum Value: +65535
Recommended Minimum Value: 1
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, CMY Colour - Cyan
Definition:
A value that may be used by an Expression to specify the Cyan field
value of the affected CMY Colour object.
AC: XCCY
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Colour Intensity Level
Definition:
A value that may be used by an Expression to specify the Intensity
Level field value of the affected Colour Index object.
AC: XCIL
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Colour Index
Definition:
A value that may be used by an Expression to specify the Index field
value of the affected Colour Index object.
AC: XCIN
Recommended Data Type: SE_UINT16
Possible Enumerators: None
Recommended Maximum Value: +65535
Recommended Minimum Value: 1
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, CMY Colour - Magenta
Definition:
A value that may be used by an Expression to specify the Magenta field
value of the affected CMY Colour object.
AC: XCMA
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, CMY Colour - Yellow
Definition:
A value that may be used by an Expression to specify the Yellow field
value of the affected CMY Colour object.
AC: XCYE
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Feature ID
Definition:
A value that may be used by an Expression to specify the ID field
value of the affected Feature ID object.
AC: XFID
Recommended Data Type: SE_UINT32
Possible Enumerators: None
Recommended Maximum Value: +4164895295
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_INDEX
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Feature State
Definition:
A value that may be used by an Expression to specify the Active State
field value of the affected State Related Feature object.
AC: XFST
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +max(float32)
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Geometry ID
Definition:
A value that may be used by an Expression to specify the ID field
value of the affected Geometry ID object.
AC: XGID
Recommended Data Type: SE_UINT32
Possible Enumerators: None
Recommended Maximum Value: +4164895295
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_INDEX
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Geometry State
Definition:
A value that may be used by an Expression to specify the Active State
field value of the affected State Related Geometry object.
AC: XGST
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +max(float32)
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Geometry Texture
Definition:
A value that may be used by an Expression to specify the Texture of
the affected Geometry object (e.g., to allow a runtime texture to be
switched to change the visual markings on a vehicle).
AC: XGTE
Recommended Data Type: SE_UINT32
Possible Enumerators: None
Recommended Maximum Value: +4164895295
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.5
Name: Control Value, HSV Colour - Hue
Definition:
A value that may be used by an Expression to specify the Hue field
value of the affected HSV Colour object.
AC: XHHU
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 360.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Heat Production Status
Definition:
A value that may be used by an Expression to specify the Heat
Production Status of the affected Geometry object (e.g., to allow a
runtime "material code" to be switched from the default IR value to a
"heat producing" IR value).
AC: XHPS
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.5
Name: Control Value, HSV Colour - Saturation
Definition:
A value that may be used by an Expression to specify the Saturation
field value of the affected HSV Colour object.
AC: XHSA
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, HSV Colour - Value
Definition:
A value that may be used by an Expression to specify the Value field
value of the affected HSV Colour object.
AC: XHVA
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Light Rendering Properties Active Light
Definition:
A value that may be used by an Expression to specify the Active Light
field value of the affected Light Rendering Properties object.
AC: XLAL
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Light Rendering Properties Candela Value
Definition:
A value that may be used by an Expression to specify the Candela Value
field value of the affected Light Rendering Properties object.
AC: XLCV
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CANDELA
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, LSR Location 3D - X
Definition:
A value that may be used by an Expression to specify the X field value
of the affected LSR Location 3D object.
AC: XLRX
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, LSR Location 3D - Y
Definition:
A value that may be used by an Expression to specify the Y field value
of the affected LSR Location 3D object.
AC: XLRY
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, LSR Location 3D - Z
Definition:
A value that may be used by an Expression to specify the Z field value
of the affected LSR Location 3D object.
AC: XLRZ
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Light Source Active
Definition:
A value that may be used by an Expression to specify the Active Light
field value of the affected Light Source object.
AC: XLSA
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Primary Display Mode
Definition:
The normal display status of the object.
AC: XPD_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_XPD__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_XPD__NORMAL_DISPLAY_ON | Normal Display (On) |
| 2 | SE_PROP_VAL_XPD__DISPLAY_PARTIALLY_SUPPRESSED | Display Partially Suppressed |
| 3 | SE_PROP_VAL_XPD__DISPLAY_FULLY_SUPPRESSED | Display Fully Suppressed |
| 997 | SE_PROP_VAL_XPD__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_XPD__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_XPD__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Control Value, Polygon Flags - Invisible
Definition:
A value that may be used by an Expression to specify the Invisible
component of the Polygon Flags field value of the affected Polygon
object.
AC: XPFI
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Polygon Flags - Collidable
Definition:
A value that may be used by an Expression to specify the Collidable
component of the Polygon Flags field value of the affected Polygon
object.
AC: XPHC
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Polygon Flags - Hat Test
Definition:
A value that may be used by an Expression to specify the Hat Test
component of the Polygon Flags field value of the affected Polygon
object.
AC: XPHT
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Polygon Flags - Laser Range Finding
Definition:
A value that may be used by an Expression to specify the Laser Range
Finding component of the Polygon Flags field value of the affected
Polygon object.
AC: XPLR
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Property Table Reference Index-On-Axis
Definition:
A value that may be used by an Expression to specify the Index-On-Axis
field value of the affected Property Table Reference object.
AC: XPRO
Recommended Data Type: SE_UINT32
Possible Enumerators: None
Recommended Maximum Value: +4164895295
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Rotation Angle
Definition:
A value that may be used by an Expression to specify the Angle field
value of the affected Rotation object.
AC: XRAN
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 360.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_DEGREE_ARC
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, RGB Colour - Blue
Definition:
A value that may be used by an Expression to specify the Blue field
value of the affected RGB Colour object.
AC: XRBL
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, RGB Colour - Green
Definition:
A value that may be used by an Expression to specify the Green field
value of the affected RGB Colour object.
AC: XRGR
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, RGB Colour - Red
Definition:
A value that may be used by an Expression to specify the Red field
value of the affected RGB Colour object.
AC: XRRE
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Reference Vector - V0
Definition:
A value that may be used by an Expression to specify the V0 field
value of the affected Reference Vector object.
AC: XRV0
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Reference Vector - V1
Definition:
A value that may be used by an Expression to specify the V1 field
value of the affected Reference Vector object.
AC: XRV1
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Reference Vector - V2
Definition:
A value that may be used by an Expression to specify the V2 field
value of the affected Reference Vector object.
AC: XRV2
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Spatial Alignment
Definition:
The existence status of the object's spatial alignment.
AC: XSA_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_XSA__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_XSA__ALIGNMENT_DEFINITE | Alignment Definite |
| 2 | SE_PROP_VAL_XSA__REPORTED_ALIGNMENT | Reported Alignment |
| 3 | SE_PROP_VAL_XSA__APPROXIMATE_ALIGNMENT | Approximate Alignment |
| 4 | SE_PROP_VAL_XSA__FEATURE_CONNECTOR | Feature Connector |
| 997 | SE_PROP_VAL_XSA__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_XSA__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_XSA__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Control Value, Scale Amount
Definition:
A value that may be used by an Expression to specify the Scale Amount
field value of the affected Scale object.
AC: XSAM
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: -max(float64)
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Sound Instance Active Value
Definition:
A value that may be used by an Expression to specify the Active Sound
Value field value of the affected Sound Instance object.
AC: XSIA
Recommended Data Type: SE_BOOLEAN
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Translation Amount
Definition:
A value that may be used by an Expression to specify the Translation
Amount field value of the affected Translation object.
AC: XTAM
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: -max(float64)
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_METER
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Texture Coordinate - S
Definition:
A value that may be used by an Expression to specify the S field value
of the affected Texture Coordinate object.
AC: XTCS
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: -max(float64)
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Texture Coordinate - T
Definition:
A value that may be used by an Expression to specify the T field value
of the affected Texture Coordinate object.
AC: XTCT
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: +max(float64)
Recommended Minimum Value: -max(float64)
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Control Value, Translucency Value
Definition:
A value that may be used by an Expression to specify the Translucency
Value field value of the affected Translucency object.
AC: XTVA
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 1.0
Recommended Minimum Value: 0.0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_CONTEXTUALLY_DETERMINED
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)