EDCS Attribute Codes: D

Label: EDCS_AC_DIRECTION_OF_CURRENT_IHO

Name: Direction of Current, Tide Reference Level

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow at tide reference level.

AC: D60_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_1_IHO

Name: Direction of Current, One Hour After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow one hour after tide reference level.

AC: D61_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_2_IHO

Name: Direction of Current, Two Hours After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow two hours after tide reference level.

AC: D62_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_3_IHO

Name: Direction of Current, Three Hours After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow three hours after tide reference level.

AC: D63_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_4_IHO

Name: Direction of Current, Four Hours After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow four hours after tide reference level.

AC: D64_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_5_IHO

Name: Direction of Current, Five Hours After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow five hours after tide reference level.

AC: D65_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_6_IHO

Name: Direction of Current, Six Hours After Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow six hours after tide reference level.

AC: D66_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_7_IHO

Name: Direction of Current, Five Hours Before Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow five hours before tide reference level.

AC: D67_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_8_IHO

Name: Direction of Current, Four Hours Before Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow four hours before tide reference level.

AC: D68_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_9_IHO

Name: Direction of Current, Three Hours Before Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow three hours before tide reference level.

AC: D69_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_10_IHO

Name: Direction of Current, Two Hours Before Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow two hours before tide reference level.

AC: D70_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT_11_IHO

Name: Direction of Current, One Hour Before Tide Reference

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow one hour before tide reference level.

AC: D71_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTION_OF_CURRENT

Name: Direction of Current, High Water

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow at high water.

AC: D80_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_1

Name: Direction of Current, One Hour

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow one hour after high water.

AC: D81_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_2

Name: Direction of Current, Two Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow two hours after high water.

AC: D82_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_3

Name: Direction of Current, Three Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow three hours after high water.

AC: D83_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_4

Name: Direction of Current, Four Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow four hours after high water.

AC: D84_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_5

Name: Direction of Current, Five Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow five hours after high water.

AC: D85_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_6

Name: Direction of Current, Six Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow six hours after high water.

AC: D86_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_7

Name: Direction of Current, Seven Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow seven hours after high water.

AC: D87_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_8

Name: Direction of Current, Eight Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow eight hours after high water.

AC: D88_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_9

Name: Direction of Current, Nine Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow nine hours after high water.

AC: D89_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_10

Name: Direction of Current, Ten Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow ten hours after high water.

AC: D90_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_CURRENT_11

Name: Direction of Current, Eleven Hours

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of current flow eleven hours after high water.

AC: D91_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DESCRIPTION_OF_AIDS_TO_NAVIGATION

Name: Description of Aids to Navigation

Definition:
Textual description of aids to navigation marking the object, e.g., "marked by buoys".

AC: DAN_

Recommended Data Type: SE_LEX_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 256

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DEPTH_BELOW_OCEAN_FLOOR

Name: Depth Below Ocean Floor

Definition:
Distance measured from the surface of the ocean floor down to the point of measurement. Recorded values are positive numbers.

AC: DBOF

Recommended Data Type: SE_FLOAT64

Possible Enumerators: None

Recommended Maximum Value: 9999.999

Recommended Minimum Value: 0.0

Recommended Significant Digits: 7

Recommended Tolerance: .001

Units: EDCS_UNITS_METER

Source: Associate inputs to support EDCS Implementation Release 2.5.3


Label: EDCS_AC_DITCH_AND_OR_BERM_TYPE

Name: Ditch and/or Berm Type

Definition:
Type of engineered ditch or berm or combination ditch/berm.

AC: DBT_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DBT__UNKNOWN Unknown
1 SE_PROP_VAL_DBT__US_ANTI_TANK_DITCH US Anti-Tank Ditch
2 SE_PROP_VAL_DBT__SOVIET_ANTI_TANK_DITCH Soviet Anti-Tank Ditch
3 SE_PROP_VAL_DBT__INFANTRY_TRENCH Infantry Trench
4 SE_PROP_VAL_DBT__EARTHEN_WALL Earthen Wall
997 SE_PROP_VAL_DBT__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DBT__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DBT__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 2.7


Label: EDCS_AC_DEWPOINT_CLIMATOLOGY_MINIMUM_CHANGE

Name: Dewpoint Climatology, Minimum Change

Definition:
The minimum difference between the dewpoint temperature at an initial time and the dewpoint temperature at an offset from that time.

AC: DCI_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +35.0

Recommended Minimum Value: -35.0

Recommended Significant Digits: 3

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEWPOINT_CLIMATOLOGY_MEAN

Name: Dewpoint Climatology, Mean

Definition:
The mean of the measured dewpoint temperatures.

AC: DCM_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.0

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DEWPOINT_CLIMATOLOGY_STD_DEV

Name: Dewpoint Climatology, Standard Deviation

Definition:
The standard deviation of the measured dewpoint temperatures.

AC: DCS_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +25.00

Recommended Minimum Value: 0.00

Recommended Significant Digits: 4

Recommended Tolerance: .01

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEWPOINT_CLIMATOLOGY_MAXIMUM_CHANGE

Name: Dewpoint Climatology, Maximum Change

Definition:
The maximum difference between the dewpoint temperature at an initial time and the dewpoint temperature at an offset from that time.

AC: DCX_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +35.0

Recommended Minimum Value: -35.0

Recommended Significant Digits: 3

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEWPOINT_DEPRESSION_SURFACE

Name: Dewpoint Depression, Surface

Definition:
The difference in degrees, at the lowest level of the atmosphere, between the air temperature and the dewpoint.

AC: DED_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +50.0

Recommended Minimum Value: -50.0

Recommended Significant Digits: 3

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DEWPOINT_ERROR

Name: Dewpoint Error

Definition:
The potential error in the dewpoint temperature of an air temperature observation.

AC: DEE_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +30.0

Recommended Minimum Value: 00.0

Recommended Significant Digits: 3

Recommended Tolerance: .1

Units: EDCS_UNITS_KELVIN

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEPTH_BELOW_SURFACE_LEVEL

Name: Depth Below Surface Level

Definition:
Distance measured from the highest point at surface level to the lowest point of the object below the surface. Recorded values are positive numbers.

AC: DEP_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: .1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEWPOINT_QUALITY

Name: Dewpoint Quality

Definition:
The quality of a dew point temperature observation. (See also DEWPOINT_TEMPERATURE_SURFACE and DEWPOINT_TEMPERATURE .)

AC: DEQ_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DEQ__UNKNOWN Unknown
1 SE_PROP_VAL_DEQ__NO_CHECK No check
2 SE_PROP_VAL_DEQ__GOOD Good
3 SE_PROP_VAL_DEQ__SUSPECT Suspect
4 SE_PROP_VAL_DEQ__ERRONEOUS Erroneous
5 SE_PROP_VAL_DEQ__ORIGINAL_VALUE_ERRONEOUS_REPLACEMENT_GOOD Original value erroneous, replacement good
6 SE_PROP_VAL_DEQ__ORIGINAL_VALUE_ERRONEOUS_REPLACEMENT_QUESTIONABLE Original value erroneous, replacement questionable
7 SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING_PROBABLY_CORRUPTED Original value missing, probably corrupted
8 SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING_RECOMPUTED_VALUE_SUSPECT Original value missing, recomputed value suspect
9 SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING Original value missing

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DEWPOINT_TEMPERATURE_SURFACE

Name: Dewpoint Temperature, Surface

Definition:
The temperature to which a parcel of air, at the lowest level of the atmosphere, must be cooled at constant pressure and water vapor content in order for saturation to occur.

AC: DES_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DEWPOINT_TEMPERATURE

Name: Dewpoint Temperature

Definition:
The temperature to which a given parcel of air must be cooled at constant pressure and water vapor content in order for saturation to occur.

AC: DET_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.0

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEWPOINT_DEPRESSION

Name: Dewpoint Depression

Definition:
The difference between the air temperature and the dewpoint.

AC: DEW_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +50.0

Recommended Minimum Value: -50.0

Recommended Significant Digits: 3

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: Associate inputs to support EDCS Implementation Release 2.5.3


Label: EDCS_AC_DIRECTION_OF_TRAFFIC_1

Name: Direction of Traffic, Primary

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of traffic, first occurrence.

AC: DF1_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_TRAFFIC_2

Name: Direction of Traffic, Secondary

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of traffic, second occurrence.

AC: DF2_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_TRAFFIC_3

Name: Direction of Traffic, Tertiary

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of traffic, third occurrence.

AC: DF3_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DIRECTION_OF_TRAFFIC_4

Name: Direction of Traffic, Quaternary

Definition:
The angle, measured in a clockwise direction, between planetary geodetic north and the direction of traffic, fourth occurrence.

AC: DF4_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DAM_FACE_TYPE

Name: Dam Face Type

Definition:
Type of face of a dam.

AC: DFT_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DFT__UNKNOWN Unknown
1 SE_PROP_VAL_DFT__VERTICAL Vertical
2 SE_PROP_VAL_DFT__SLOPE Slope
997 SE_PROP_VAL_DFT__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DFT__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DFT__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DROP_GATE_CATEGORY

Name: Drop Gate Category

Definition:
Distinguishes between two drop gate types.

AC: DGC_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DGC__UNKNOWN Unknown
1 SE_PROP_VAL_DGC__OVERHEAD_DROP Overhead Drop
2 SE_PROP_VAL_DGC__SIDE_DROP Side Drop
997 SE_PROP_VAL_DGC__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DGC__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DGC__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DIRECTIVITY

Name: Directivity

Definition:
The side or sides of the object which produces the greatest reflectivity potential to electromagnetic radiation.

AC: DIR_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DIR__UNKNOWN Unknown
1 SE_PROP_VAL_DIR__UNI Uni
2 SE_PROP_VAL_DIR__BI Bi
3 SE_PROP_VAL_DIR__OMNI Omni
997 SE_PROP_VAL_DIR__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DIR__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DIR__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_MATERIAL

Name: Density, Material

Definition:
The mass per unit volume of a material.

AC: DMA_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_KILOGRAMS_PER_CUBIC_METER

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_DENSITY_MEASURE_BRUSH_OR_UNDERGROWTH

Name: Density Measure (Brush / Undergrowth)

Definition:
Fraction of ground covered by undergrowth.

AC: DMB_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 100

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_MEASURE_FEATURE_COUNT

Name: Density Measure (Object Count)

Definition:
Indicates the number of objects of this type within an area.

AC: DMF_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: 0

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_MEASURE_FEATURE_COUNT_ALL

Name: Density Measure (Object Count - All)

Definition:
Indicates the number of objects of all types within an area.

AC: DMFA

Recommended Data Type: SE_UINT32

Possible Enumerators: None

Recommended Maximum Value: +4164895295

Recommended Minimum Value: 0

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_DENSITY_MEASURE_PERCENT_OF_KELP_COVER

Name: Density Measure (Fractional Kelp Cover)

Definition:
Concentration of kelp weed in the sea, measured in fractional coverage within the delineated object extents.

AC: DMK_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 100

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DENSITY_MEASURE_PERCENT_OF_ROOF_COVER

Name: Density Measure (Fractional Roof Cover)

Definition:
Roof cover measured by fraction within the delineated object extents.

AC: DMR_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 100

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_MEASURE_STRUCTURE_COUNT

Name: Density Measure (Structure Count)

Definition:
Density of structures within a square kilometer (determined as the total count per 1000m x 1000m).

AC: DMS_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_MEASURE_PERCENT_OF_TREE_OR_CANOPY_COVER

Name: Density Measure (Fractional Tree / Canopy Cover)

Definition:
Canopy cover measured by fraction within the delineated object extents during the summer season.

AC: DMT_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 100

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_UNITLESS

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_FISHING_VESSELS

Name: Density, Fishing Vessels

Definition:
Number of fishing vessels (gross weight > 1000 tons; length > 18 meters) in one arc degree square cell.

AC: DNF_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DENSITY_LARGE_TANKERS

Name: Density, Large Tankers

Definition:
Number of large tankers (dead weight = 175,000 to 350,000 tons; length = 300 to 325 meters) in one arc degree square cell.

AC: DNL_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DENSITY_MERCHANT_VESSELS

Name: Density, Merchant Vessels

Definition:
Number of merchant vessels (gross weight > 1000 tons; length > 18 meters) in one arc degree square cell.

AC: DNM_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DENSITY_SUPERTANKERS

Name: Density, Supertankers

Definition:
Number of supertankers (dead weight > 350,000 tons; length > 325 meters) in one arc degree square cell.

AC: DNS_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DENSITY_SHIPS_CATEGORY

Name: Density, Ships - Category

Definition:
Categorization of shipping traffic density.

AC: DNSC

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DNSC_UNKNOWN Unknown
1 SE_PROP_VAL_DNSC_REMOTE Remote
2 SE_PROP_VAL_DNSC_LIGHT Light
3 SE_PROP_VAL_DNSC_MODERATE Moderate
4 SE_PROP_VAL_DNSC_HEAVY Heavy

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DENSITY_SHIPS_ESTIMATE

Name: Density, Ships - Estimate

Definition:
The spatial density of ships calculated as the number in a one arc degree square cell.

AC: DNSE

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DENSITY_TANKERS

Name: Density, Tankers

Definition:
Number of tankers (gross weight > 1000 tons; dead weight < 175,000 tons; length = 18 to 300 meters) in one arc degree square cell.

AC: DNT_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 50.0000

Recommended Minimum Value: 0.0000

Recommended Significant Digits: 6

Recommended Tolerance: .0001

Units: EDCS_UNITS_UNITLESS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DIRECTION_OF_FLOW

Name: Direction of Flow

Definition:
Bearing of movement or direction of the flow.

AC: DOF_

Recommended Data Type: SE_UINT8

Possible Enumerators: None

Recommended Maximum Value: 359

Recommended Minimum Value: 0

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.0


Label: EDCS_AC_DAY_OF_YEAR

Name: Day of Year

Definition:
Ordinal index of the day within the year, starting with "1" on January 1st.

AC: DOY_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: 366

Recommended Minimum Value: 1

Recommended Significant Digits: 3

Recommended Tolerance: 1

Units: EDCS_UNITS_DAY

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_HIGHEST_LEVEL_OF_GROUND_WATER

Name: Highest Level of Ground Water

Definition:
Highest annual average level of ground water.

AC: DP1_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0


Label: EDCS_AC_LOWEST_LEVEL_OF_GROUND_WATER

Name: Lowest Level of Ground Water

Definition:
Lowest annual average level of ground water.

AC: DP2_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEFENSIVE_POSITION_TYPE

Name: Defensive Position Type

Definition:
Type of military defensive position.

AC: DPT_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DPT__UNKNOWN Unknown
1 SE_PROP_VAL_DPT__DELIBERATE_PER_DEF_POS_NO_COVER Deliberate Personnel Defensive Position without Overhead Cover
2 SE_PROP_VAL_DPT__DELIBERATE_PER_DEF_POS_WITH_COVER Deliberate Personnel Defensive Position with Overhead Cover
3 SE_PROP_VAL_DPT__HASTY_PER_DEF_POS Hasty Personnel Defensive Position
4 SE_PROP_VAL_DPT__DELIBERATE_VEH_DEF_POS_WITHOUT_FULL_HIDE Deliberate Vehicle Defensive Position without Full Hide
5 SE_PROP_VAL_DPT__DELIBERATE_VEH_DEF_POS_WITH_FULL_HIDE Deliberate Vehicle Defensive Position with Full Hide
6 SE_PROP_VAL_DPT__HASTY_VEH_DEF_POS Hasty Vehicle Defensive Position
999 SE_PROP_VAL_DPT__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)


Label: EDCS_AC_DEPTH_RANGE_VALUE_1

Name: Depth Range, Minimum

Definition:
Minimum value of a depth range.

AC: DR1_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEPTH_RANGE_VALUE_2

Name: Depth Range, Maximum

Definition:
Maximum value of a depth range.

AC: DR2_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEPTH_RANGE_GT_ONE_METER_RESOLUTION_VALUE_1

Name: Depth Range with Greater than 1 Meter Resolution, Minimum

Definition:
Minimum value of a depth range.

AC: DR3_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: .1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DEPTH_RANGE_GT_ONE_METER_RESOLUTION_VALUE_2

Name: Depth Range with Greater than 1 Meter Resolution, Maximum

Definition:
Maximum value of a depth range.

AC: DR4_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: .1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DESCRIPTION_OF_REFERENCE_POINT

Name: Description of Reference Point

Definition:
Description of the object(s) which form a Leading Line or Clearing Line.

AC: DRP_

Recommended Data Type: SE_LEX_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 256

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: DIGEST Edition 2.0


Label: EDCS_AC_DENSITY_OF_WOODY_VEGETATION_RANGE

Name: Density of Woody Vegetation Range

Definition:
Range indicating fraction of total ground surface covered by objects identified as TREES or SCRUB_OR_BRUSH_OR_BUSH within the delineated object extents.

AC: DRW_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DRW__UNKNOWN Unknown
1 SE_PROP_VAL_DRW__gt0prcnt_AND_le5prcnt > 0% and <= 5%
2 SE_PROP_VAL_DRW__gt5prcnt_AND_le15prcnt > 5% and <= 15%
3 SE_PROP_VAL_DRW__gt15prcnt > 15%
4 SE_PROP_VAL_DRW__NOT_APPLICABLE Not Applicable
997 SE_PROP_VAL_DRW__DATA_WITHHELD Data Withheld
999 SE_PROP_VAL_DRW__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_DATE_END

Name: Date End

Definition:
Latest date on which the object (e.g., a buoy) will be present. Coded YYYYMMDD.

AC: DTE_

Recommended Data Type: SE_STR_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 8

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DEWPOINT_TEMPERATURE_MINIMUM

Name: Dewpoint Temperature, Minimum

Definition:
The minimum dew-point temperature from a series of samples taken during the reporting period.

AC: DTI_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.0

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_DEWPOINT_TEMPERATURE_MEAN

Name: Dewpoint Temperature, Mean

Definition:
The mean temperature to which a given parcel of air must be cooled at constant pressure and water vapor content in order for saturation to occur.

AC: DTM_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.0

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DATE_START

Name: Date Start

Definition:
Earliest date on which the object (e.g., a buoy) will be present. Coded YYYYMMDD.

AC: DTS_

Recommended Data Type: SE_STR_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 8

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: DIGEST Edition 2.0a


Label: EDCS_AC_DRAGON_TEETH_TYPE

Name: Dragon Teeth Type

Definition:
The type of a dragon teeth obstacle.

AC: DTT_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DTT__UNKNOWN Unknown
1 SE_PROP_VAL_DTT__STEEL_HEDGEHOG Steel Hedgehog
2 SE_PROP_VAL_DTT__STEEL_TETRAHEDRON Steel Tetrahedron
3 SE_PROP_VAL_DTT__CONCRETE_BLOCK Concrete Block
4 SE_PROP_VAL_DTT__CONCRETE_TETRAHEDRON Concrete Tetrahedron
5 SE_PROP_VAL_DTT__LOG_POST Log Post
997 SE_PROP_VAL_DTT__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DTT__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DTT__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 2.7


Label: EDCS_AC_DEWPOINT_TEMPERATURE_MAXIMUM

Name: Dewpoint Temperature, Maximum

Definition:
The maximum dew-point temperature from a series of samples taken during the reporting period.

AC: DTX_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +63.0

Recommended Minimum Value: -110.0

Recommended Significant Digits: 4

Recommended Tolerance: .1

Units: EDCS_UNITS_DEGREE_CELSIUS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_UNITS_OF_DEPTH_MEASUREMENT

Name: Units, Depth

Definition:
Unit of depth measurement.

AC: DUN_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DUN__UNKNOWN Unknown
1 SE_PROP_VAL_DUN__METERS Meters
2 SE_PROP_VAL_DUN__FATHOMS_AND_FEET Fathoms and Feet
3 SE_PROP_VAL_DUN__FEET Feet
4 SE_PROP_VAL_DUN__FATHOMS_AND_FRACTIONS Fathoms and Fractions
997 SE_PROP_VAL_DUN__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DUN__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DUN__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.1


Label: EDCS_AC_DEPTH_OF_WATER_1

Name: Depth of Water, First Range

Definition:
Predominant water depth within delineation of the object, determined at the greatest depth along a cross section of the object (First Range).

AC: DW1_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DW1__UNKNOWN Unknown
1 SE_PROP_VAL_DW1__le0pt8 <= 0.8
2 SE_PROP_VAL_DW1__gt0pt8_AND_le1pt6 > 0.8 and <= 1.6
3 SE_PROP_VAL_DW1__gt1pt6_AND_le2pt4 > 1.6 and <= 2.4
4 SE_PROP_VAL_DW1__gt2pt4 > 2.4
5 SE_PROP_VAL_DW1__NA NA
997 SE_PROP_VAL_DW1__DATA_WITHHELD Data Withheld
999 SE_PROP_VAL_DW1__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEPTH_OF_WATER_2

Name: Depth of Water, Second Range

Definition:
Predominant water depth within delineation of the object, determined at the greatest depth along a cross section of the object (Second Range).

AC: DW2_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DW2__UNKNOWN Unknown
1 SE_PROP_VAL_DW2__le1pt6 <= 1.6
2 SE_PROP_VAL_DW2__gt1pt6_AND_le2pt4 > 1.6 and <= 2.4
3 SE_PROP_VAL_DW2__gt2pt4 > 2.4
4 SE_PROP_VAL_DW2__NA NA
997 SE_PROP_VAL_DW2__DATA_WITHHELD Data Withheld
999 SE_PROP_VAL_DW2__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_DEPTH_WATER_BATHYMETRIC

Name: Depth of Water, Bathymetric

Definition:
The depth of the water from a specified vertical datum to the sea floor. Recorded values are positive numbers. (See also VERTICAL_SOUNDING_DATUM_CATEGORY .)

AC: DWB_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 12000.00

Recommended Minimum Value: -100.00

Recommended Significant Digits: 7

Recommended Tolerance: .01

Units: EDCS_UNITS_METER

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_DEPTH_WATER_BATHYMETRIC_MEAN

Name: Depth of Water, Bathymetric - Mean

Definition:
The average depth of the water from a specified vertical datum to the sea floor. Recorded values are positive numbers. (See also VERTICAL_SOUNDING_DATUM_CATEGORY .)

AC: DWM_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 12000.00

Recommended Minimum Value: -100.00

Recommended Significant Digits: 7

Recommended Tolerance: .01

Units: EDCS_UNITS_METER

Source: Associate inputs to support EDCS Implementation Release 1.34


Label: EDCS_AC_HYDROGRAPHIC_BARRIER_TYPE

Name: Hydrographic Barrier Type

Definition:
Differentiates the type of barrier to hydrographic flow an object presents (e.g., dam, weir, rapids).

AC: DWT_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_DWT__UNKNOWN Unknown
1 SE_PROP_VAL_DWT__WEIR Weir
2 SE_PROP_VAL_DWT__DAM Dam
3 SE_PROP_VAL_DWT__LOCK Lock
4 SE_PROP_VAL_DWT__RAPIDS Rapids
5 SE_PROP_VAL_DWT__WATERFALL Waterfall
6 SE_PROP_VAL_DWT__NAUTICAL_GATE Nautical Gate
997 SE_PROP_VAL_DWT__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_DWT__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_DWT__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.1


Prev:AC_C.htm Next:AC_E.htm Up:Index