Name: Direction of Current, Tide Reference Level
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow at tide reference
level.
AC: D60_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, One Hour After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow one hour after tide
reference level.
AC: D61_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Two Hours After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow two hours after tide
reference level.
AC: D62_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Three Hours After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow three hours after
tide reference level.
AC: D63_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Four Hours After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow four hours after
tide reference level.
AC: D64_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Five Hours After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow five hours after
tide reference level.
AC: D65_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Six Hours After Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow six hours after tide
reference level.
AC: D66_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Five Hours Before Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow five hours before
tide reference level.
AC: D67_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Four Hours Before Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow four hours before
tide reference level.
AC: D68_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Three Hours Before Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow three hours before
tide reference level.
AC: D69_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, Two Hours Before Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow two hours before
tide reference level.
AC: D70_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, One Hour Before Tide Reference
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow one hour before tide
reference level.
AC: D71_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0a
Name: Direction of Current, High Water
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow at high water.
AC: D80_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, One Hour
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow one hour after high
water.
AC: D81_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Two Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow two hours after high
water.
AC: D82_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Three Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow three hours after
high water.
AC: D83_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Four Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow four hours after
high water.
AC: D84_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Five Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow five hours after
high water.
AC: D85_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Six Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow six hours after high
water.
AC: D86_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Seven Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow seven hours after
high water.
AC: D87_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Eight Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow eight hours after
high water.
AC: D88_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Nine Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow nine hours after
high water.
AC: D89_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Ten Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow ten hours after high
water.
AC: D90_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Current, Eleven Hours
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of current flow eleven hours after
high water.
AC: D91_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Description of Aids to Navigation
Definition:
Textual description of aids to navigation marking the object, e.g.,
"marked by buoys".
AC: DAN_
Recommended Data Type: SE_LEX_STRING
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: 256
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: DIGEST Edition 2.0a
Name: Depth Below Ocean Floor
Definition:
Distance measured from the surface of the ocean floor down to the
point of measurement. Recorded values are positive numbers.
AC: DBOF
Recommended Data Type: SE_FLOAT64
Possible Enumerators: None
Recommended Maximum Value: 9999.999
Recommended Minimum Value: 0.0
Recommended Significant Digits: 7
Recommended Tolerance: .001
Units: EDCS_UNITS_METER
Source: Associate inputs to support EDCS Implementation Release 2.5.3
Name: Ditch and/or Berm Type
Definition:
Type of engineered ditch or berm or combination ditch/berm.
AC: DBT_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DBT__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DBT__US_ANTI_TANK_DITCH | US Anti-Tank Ditch |
| 2 | SE_PROP_VAL_DBT__SOVIET_ANTI_TANK_DITCH | Soviet Anti-Tank Ditch |
| 3 | SE_PROP_VAL_DBT__INFANTRY_TRENCH | Infantry Trench |
| 4 | SE_PROP_VAL_DBT__EARTHEN_WALL | Earthen Wall |
| 997 | SE_PROP_VAL_DBT__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DBT__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DBT__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: Associate inputs to support EDCS Implementation Release 2.7
Name: Dewpoint Climatology, Minimum Change
Definition:
The minimum difference between the dewpoint temperature at an initial
time and the dewpoint temperature at an offset from that time.
AC: DCI_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +35.0
Recommended Minimum Value: -35.0
Recommended Significant Digits: 3
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Dewpoint Climatology, Mean
Definition:
The mean of the measured dewpoint temperatures.
AC: DCM_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.0
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Dewpoint Climatology, Standard Deviation
Definition:
The standard deviation of the measured dewpoint temperatures.
AC: DCS_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +25.00
Recommended Minimum Value: 0.00
Recommended Significant Digits: 4
Recommended Tolerance: .01
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Dewpoint Climatology, Maximum Change
Definition:
The maximum difference between the dewpoint temperature at an initial
time and the dewpoint temperature at an offset from that time.
AC: DCX_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +35.0
Recommended Minimum Value: -35.0
Recommended Significant Digits: 3
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Dewpoint Depression, Surface
Definition:
The difference in degrees, at the lowest level of the atmosphere,
between the air temperature and the dewpoint.
AC: DED_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +50.0
Recommended Minimum Value: -50.0
Recommended Significant Digits: 3
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Dewpoint Error
Definition:
The potential error in the dewpoint temperature of an air temperature
observation.
AC: DEE_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +30.0
Recommended Minimum Value: 00.0
Recommended Significant Digits: 3
Recommended Tolerance: .1
Units: EDCS_UNITS_KELVIN
Source: JMCDM inputs 8-11-98
Name: Depth Below Surface Level
Definition:
Distance measured from the highest point at surface level to the
lowest point of the object below the surface. Recorded values are
positive numbers.
AC: DEP_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: .1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0
Name: Dewpoint Quality
Definition:
The quality of a dew point temperature observation. (See also
DEWPOINT_TEMPERATURE_SURFACE
and DEWPOINT_TEMPERATURE
.)
AC: DEQ_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DEQ__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DEQ__NO_CHECK | No check |
| 2 | SE_PROP_VAL_DEQ__GOOD | Good |
| 3 | SE_PROP_VAL_DEQ__SUSPECT | Suspect |
| 4 | SE_PROP_VAL_DEQ__ERRONEOUS | Erroneous |
| 5 | SE_PROP_VAL_DEQ__ORIGINAL_VALUE_ERRONEOUS_REPLACEMENT_GOOD | Original value erroneous, replacement good |
| 6 | SE_PROP_VAL_DEQ__ORIGINAL_VALUE_ERRONEOUS_REPLACEMENT_QUESTIONABLE | Original value erroneous, replacement questionable |
| 7 | SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING_PROBABLY_CORRUPTED | Original value missing, probably corrupted |
| 8 | SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING_RECOMPUTED_VALUE_SUSPECT | Original value missing, recomputed value suspect |
| 9 | SE_PROP_VAL_DEQ__ORIGINAL_VALUE_MISSING | Original value missing |
Units: EDCS_UNITS_ENUMERATION
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Dewpoint Temperature, Surface
Definition:
The temperature to which a parcel of air, at the lowest level of the
atmosphere, must be cooled at constant pressure and water vapor
content in order for saturation to occur.
AC: DES_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Dewpoint Temperature
Definition:
The temperature to which a given parcel of air must be cooled at
constant pressure and water vapor content in order for saturation to
occur.
AC: DET_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.0
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Dewpoint Depression
Definition:
The difference between the air temperature and the dewpoint.
AC: DEW_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +50.0
Recommended Minimum Value: -50.0
Recommended Significant Digits: 3
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: Associate inputs to support EDCS Implementation Release 2.5.3
Name: Direction of Traffic, Primary
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of traffic, first occurrence.
AC: DF1_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Traffic, Secondary
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of traffic, second occurrence.
AC: DF2_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Traffic, Tertiary
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of traffic, third occurrence.
AC: DF3_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Direction of Traffic, Quaternary
Definition:
The angle, measured in a clockwise direction, between planetary
geodetic north and the direction of traffic, fourth occurrence.
AC: DF4_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Dam Face Type
Definition:
Type of face of a dam.
AC: DFT_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DFT__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DFT__VERTICAL | Vertical |
| 2 | SE_PROP_VAL_DFT__SLOPE | Slope |
| 997 | SE_PROP_VAL_DFT__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DFT__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DFT__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0a
Name: Drop Gate Category
Definition:
Distinguishes between two drop gate types.
AC: DGC_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DGC__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DGC__OVERHEAD_DROP | Overhead Drop |
| 2 | SE_PROP_VAL_DGC__SIDE_DROP | Side Drop |
| 997 | SE_PROP_VAL_DGC__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DGC__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DGC__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0a
Name: Directivity
Definition:
The side or sides of the object which produces the greatest
reflectivity potential to electromagnetic radiation.
AC: DIR_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DIR__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DIR__UNI | Uni |
| 2 | SE_PROP_VAL_DIR__BI | Bi |
| 3 | SE_PROP_VAL_DIR__OMNI | Omni |
| 997 | SE_PROP_VAL_DIR__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DIR__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DIR__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Density, Material
Definition:
The mass per unit volume of a material.
AC: DMA_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_KILOGRAMS_PER_CUBIC_METER
Source: Associate inputs to support EDCS Implementation Release 2.5
Name: Density Measure (Brush / Undergrowth)
Definition:
Fraction of ground covered by undergrowth.
AC: DMB_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 100
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0
Name: Density Measure (Object Count)
Definition:
Indicates the number of objects of this type within an area.
AC: DMF_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0
Name: Density Measure (Object Count - All)
Definition:
Indicates the number of objects of all types within an area.
AC: DMFA
Recommended Data Type: SE_UINT32
Possible Enumerators: None
Recommended Maximum Value: +4164895295
Recommended Minimum Value: 0
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 2.5
Name: Density Measure (Fractional Kelp Cover)
Definition:
Concentration of kelp weed in the sea, measured in fractional coverage
within the delineated object extents.
AC: DMK_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 100
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0a
Name: Density Measure (Fractional Roof Cover)
Definition:
Roof cover measured by fraction within the delineated object extents.
AC: DMR_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 100
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0
Name: Density Measure (Structure Count)
Definition:
Density of structures within a square kilometer (determined as the
total count per 1000m x 1000m).
AC: DMS_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: -32767
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0
Name: Density Measure (Fractional Tree / Canopy Cover)
Definition:
Canopy cover measured by fraction within the delineated object extents
during the summer season.
AC: DMT_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 100
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_UNITLESS
Source: DIGEST Edition 2.0
Name: Density, Fishing Vessels
Definition:
Number of fishing vessels (gross weight > 1000 tons; length > 18
meters) in one arc degree square cell.
AC: DNF_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Density, Large Tankers
Definition:
Number of large tankers (dead weight = 175,000 to 350,000 tons; length
= 300 to 325 meters) in one arc degree square cell.
AC: DNL_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Density, Merchant Vessels
Definition:
Number of merchant vessels (gross weight > 1000 tons; length > 18
meters) in one arc degree square cell.
AC: DNM_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Density, Supertankers
Definition:
Number of supertankers (dead weight > 350,000 tons; length > 325
meters) in one arc degree square cell.
AC: DNS_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Density, Ships - Category
Definition:
Categorization of shipping traffic density.
AC: DNSC
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DNSC_UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DNSC_REMOTE | Remote |
| 2 | SE_PROP_VAL_DNSC_LIGHT | Light |
| 3 | SE_PROP_VAL_DNSC_MODERATE | Moderate |
| 4 | SE_PROP_VAL_DNSC_HEAVY | Heavy |
Units: EDCS_UNITS_ENUMERATION
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Density, Ships - Estimate
Definition:
The spatial density of ships calculated as the number in a one arc
degree square cell.
AC: DNSE
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: JMCDM inputs 8-11-98
Name: Density, Tankers
Definition:
Number of tankers (gross weight > 1000 tons; dead weight < 175,000
tons; length = 18 to 300 meters) in one arc degree square cell.
AC: DNT_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 50.0000
Recommended Minimum Value: 0.0000
Recommended Significant Digits: 6
Recommended Tolerance: .0001
Units: EDCS_UNITS_UNITLESS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Direction of Flow
Definition:
Bearing of movement or direction of the flow.
AC: DOF_
Recommended Data Type: SE_UINT8
Possible Enumerators: None
Recommended Maximum Value: 359
Recommended Minimum Value: 0
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DEGREE_ARC
Source: DIGEST Edition 2.0
Name: Day of Year
Definition:
Ordinal index of the day within the year, starting with "1" on January
1st.
AC: DOY_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: 366
Recommended Minimum Value: 1
Recommended Significant Digits: 3
Recommended Tolerance: 1
Units: EDCS_UNITS_DAY
Source: Associate inputs to support EDCS Implementation Release 2.5
Name: Highest Level of Ground Water
Definition:
Highest annual average level of ground water.
AC: DP1_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: -32767
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0
Name: Lowest Level of Ground Water
Definition:
Lowest annual average level of ground water.
AC: DP2_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: -32767
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0
Name: Defensive Position Type
Definition:
Type of military defensive position.
AC: DPT_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DPT__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DPT__DELIBERATE_PER_DEF_POS_NO_COVER | Deliberate Personnel Defensive Position without Overhead Cover |
| 2 | SE_PROP_VAL_DPT__DELIBERATE_PER_DEF_POS_WITH_COVER | Deliberate Personnel Defensive Position with Overhead Cover |
| 3 | SE_PROP_VAL_DPT__HASTY_PER_DEF_POS | Hasty Personnel Defensive Position |
| 4 | SE_PROP_VAL_DPT__DELIBERATE_VEH_DEF_POS_WITHOUT_FULL_HIDE | Deliberate Vehicle Defensive Position without Full Hide |
| 5 | SE_PROP_VAL_DPT__DELIBERATE_VEH_DEF_POS_WITH_FULL_HIDE | Deliberate Vehicle Defensive Position with Full Hide |
| 6 | SE_PROP_VAL_DPT__HASTY_VEH_DEF_POS | Hasty Vehicle Defensive Position |
| 999 | SE_PROP_VAL_DPT__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: Associate inputs to support EDCS Implementation Release 2.0 (aka SDK)
Name: Depth Range, Minimum
Definition:
Minimum value of a depth range.
AC: DR1_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: -32767
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0
Name: Depth Range, Maximum
Definition:
Maximum value of a depth range.
AC: DR2_
Recommended Data Type: SE_INT16
Possible Enumerators: None
Recommended Maximum Value: +32767
Recommended Minimum Value: -32767
Recommended Significant Digits: Not Applicable
Recommended Tolerance: 1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0
Name: Depth Range with Greater than 1 Meter Resolution, Minimum
Definition:
Minimum value of a depth range.
AC: DR3_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: .1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0a
Name: Depth Range with Greater than 1 Meter Resolution, Maximum
Definition:
Maximum value of a depth range.
AC: DR4_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: Not Applicable
Recommended Tolerance: .1
Units: EDCS_UNITS_METER
Source: DIGEST Edition 2.0a
Name: Description of Reference Point
Definition:
Description of the object(s) which form a Leading Line or Clearing
Line.
AC: DRP_
Recommended Data Type: SE_LEX_STRING
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: 256
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: DIGEST Edition 2.0
Name: Density of Woody Vegetation Range
Definition:
Range indicating fraction of total ground surface covered by objects
identified as TREES or SCRUB_OR_BRUSH_OR_BUSH within the delineated
object extents.
AC: DRW_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DRW__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DRW__gt0prcnt_AND_le5prcnt | > 0% and <= 5% |
| 2 | SE_PROP_VAL_DRW__gt5prcnt_AND_le15prcnt | > 5% and <= 15% |
| 3 | SE_PROP_VAL_DRW__gt15prcnt | > 15% |
| 4 | SE_PROP_VAL_DRW__NOT_APPLICABLE | Not Applicable |
| 997 | SE_PROP_VAL_DRW__DATA_WITHHELD | Data Withheld |
| 999 | SE_PROP_VAL_DRW__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Date End
Definition:
Latest date on which the object (e.g., a buoy) will be present. Coded
YYYYMMDD.
AC: DTE_
Recommended Data Type: SE_STR_STRING
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: 8
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: DIGEST Edition 2.0a
Name: Dewpoint Temperature, Minimum
Definition:
The minimum dew-point temperature from a series of samples taken
during the reporting period.
AC: DTI_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.0
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Dewpoint Temperature, Mean
Definition:
The mean temperature to which a given parcel of air must be cooled at
constant pressure and water vapor content in order for saturation to
occur.
AC: DTM_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.0
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Date Start
Definition:
Earliest date on which the object (e.g., a buoy) will be present.
Coded YYYYMMDD.
AC: DTS_
Recommended Data Type: SE_STR_STRING
Possible Enumerators: None
Recommended Maximum Value: Not Applicable
Recommended Minimum Value: Not Applicable
Recommended Significant Digits: 8
Recommended Tolerance: Not Applicable
Units: EDCS_UNITS_UNITS_NOT_APPLICABLE
Source: DIGEST Edition 2.0a
Name: Dragon Teeth Type
Definition:
The type of a dragon teeth obstacle.
AC: DTT_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DTT__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DTT__STEEL_HEDGEHOG | Steel Hedgehog |
| 2 | SE_PROP_VAL_DTT__STEEL_TETRAHEDRON | Steel Tetrahedron |
| 3 | SE_PROP_VAL_DTT__CONCRETE_BLOCK | Concrete Block |
| 4 | SE_PROP_VAL_DTT__CONCRETE_TETRAHEDRON | Concrete Tetrahedron |
| 5 | SE_PROP_VAL_DTT__LOG_POST | Log Post |
| 997 | SE_PROP_VAL_DTT__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DTT__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DTT__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: Associate inputs to support EDCS Implementation Release 2.7
Name: Dewpoint Temperature, Maximum
Definition:
The maximum dew-point temperature from a series of samples taken
during the reporting period.
AC: DTX_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: +63.0
Recommended Minimum Value: -110.0
Recommended Significant Digits: 4
Recommended Tolerance: .1
Units: EDCS_UNITS_DEGREE_CELSIUS
Source: JMCDM inputs 8-11-98
Name: Units, Depth
Definition:
Unit of depth measurement.
AC: DUN_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DUN__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DUN__METERS | Meters |
| 2 | SE_PROP_VAL_DUN__FATHOMS_AND_FEET | Fathoms and Feet |
| 3 | SE_PROP_VAL_DUN__FEET | Feet |
| 4 | SE_PROP_VAL_DUN__FATHOMS_AND_FRACTIONS | Fathoms and Fractions |
| 997 | SE_PROP_VAL_DUN__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DUN__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DUN__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.1
Name: Depth of Water, First Range
Definition:
Predominant water depth within delineation of the object, determined
at the greatest depth along a cross section of the object (First
Range).
AC: DW1_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DW1__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DW1__le0pt8 | <= 0.8 |
| 2 | SE_PROP_VAL_DW1__gt0pt8_AND_le1pt6 | > 0.8 and <= 1.6 |
| 3 | SE_PROP_VAL_DW1__gt1pt6_AND_le2pt4 | > 1.6 and <= 2.4 |
| 4 | SE_PROP_VAL_DW1__gt2pt4 | > 2.4 |
| 5 | SE_PROP_VAL_DW1__NA | NA |
| 997 | SE_PROP_VAL_DW1__DATA_WITHHELD | Data Withheld |
| 999 | SE_PROP_VAL_DW1__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Depth of Water, Second Range
Definition:
Predominant water depth within delineation of the object, determined
at the greatest depth along a cross section of the object (Second
Range).
AC: DW2_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DW2__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DW2__le1pt6 | <= 1.6 |
| 2 | SE_PROP_VAL_DW2__gt1pt6_AND_le2pt4 | > 1.6 and <= 2.4 |
| 3 | SE_PROP_VAL_DW2__gt2pt4 | > 2.4 |
| 4 | SE_PROP_VAL_DW2__NA | NA |
| 997 | SE_PROP_VAL_DW2__DATA_WITHHELD | Data Withheld |
| 999 | SE_PROP_VAL_DW2__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.0
Name: Depth of Water, Bathymetric
Definition:
The depth of the water from a specified vertical datum to the sea
floor. Recorded values are positive numbers. (See also
VERTICAL_SOUNDING_DATUM_CATEGORY
.)
AC: DWB_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 12000.00
Recommended Minimum Value: -100.00
Recommended Significant Digits: 7
Recommended Tolerance: .01
Units: EDCS_UNITS_METER
Source: JMCDM inputs 8-11-98
Name: Depth of Water, Bathymetric - Mean
Definition:
The average depth of the water from a specified vertical datum to the
sea floor. Recorded values are positive numbers. (See also
VERTICAL_SOUNDING_DATUM_CATEGORY
.)
AC: DWM_
Recommended Data Type: SE_FLOAT32
Possible Enumerators: None
Recommended Maximum Value: 12000.00
Recommended Minimum Value: -100.00
Recommended Significant Digits: 7
Recommended Tolerance: .01
Units: EDCS_UNITS_METER
Source: Associate inputs to support EDCS Implementation Release 1.34
Name: Hydrographic Barrier Type
Definition:
Differentiates the type of barrier to hydrographic flow an object
presents (e.g., dam, weir, rapids).
AC: DWT_
Recommended Data Type: EDCS_AC_ENUM_VALUE
Possible Enumerators:
| 0 | SE_PROP_VAL_DWT__UNKNOWN | Unknown |
|---|---|---|
| 1 | SE_PROP_VAL_DWT__WEIR | Weir |
| 2 | SE_PROP_VAL_DWT__DAM | Dam |
| 3 | SE_PROP_VAL_DWT__LOCK | Lock |
| 4 | SE_PROP_VAL_DWT__RAPIDS | Rapids |
| 5 | SE_PROP_VAL_DWT__WATERFALL | Waterfall |
| 6 | SE_PROP_VAL_DWT__NAUTICAL_GATE | Nautical Gate |
| 997 | SE_PROP_VAL_DWT__DATA_WITHHELD | Data Withheld |
| 998 | SE_PROP_VAL_DWT__NOT_APPLICABLE_OR_POINT_EXCLUDED | Not Applicable / Point Excluded |
| 999 | SE_PROP_VAL_DWT__OTHER | Other |
Units: EDCS_UNITS_ENUMERATION
Source: DIGEST Edition 2.1