EDCS Attribute Codes: G

Label: EDCS_AC_GAUGE_WIDTH

Name: Gauge Width

Definition:
The width of a single pair of rails, measured along the shortest distance from inside rail to inside rail.

AC: GAW_

Recommended Data Type: SE_INT16

Possible Enumerators: None

Recommended Maximum Value: +32767

Recommended Minimum Value: -32767

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_CENTIMETER

Source: DIGEST Edition 2.0


Label: EDCS_AC_GEOMORPHIC_HEIGHT

Name: Geomorphic Height

Definition:
Height of the object above average surface level as determined by a corresponding digital elevation matrix.

AC: GEH_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0a


Label: EDCS_AC_GENERATION_OF_FOG_SIGNAL_CATEGORY

Name: Generation of Fog Signal Category

Definition:
Type of mechanism of fog signal generating.

AC: GEN_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GEN__UNDEFINED Undefined
1 SE_PROP_VAL_GEN__AUTOMATICALLY Automatically
2 SE_PROP_VAL_GEN__BY_WAVE_ACTION By Wave Action
3 SE_PROP_VAL_GEN__BY_HAND By Hand
4 SE_PROP_VAL_GEN__BY_WIND By Wind
997 SE_PROP_VAL_GEN__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GEN__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GEN__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GEOGRAPHIC_LOCATION_CATEGORY

Name: Geographic Location Category

Definition:
Describes the general geographic location of the object.

AC: GEO_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GEO__UNKNOWN Unknown
1 SE_PROP_VAL_GEO__ARCTIC Arctic
997 SE_PROP_VAL_GEO__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GEO__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GEO__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GTRS_GEOTILE_IDENTIFICATION

Name: GTRS Geotile Identification

Definition:
Identifies a specific geotile within the Geotile Reference System (GTRS), by a 6-digit alphanumeric designation: the first two letters are the encompassing GTRS megatile, the next two digits are the easting index of the geotile within the megatile, and the last two digits are the northing index of the geotile within the megatile.

AC: GGI_

Recommended Data Type: SE_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 6

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOPOTENTIAL_HEIGHT_CLIMATOLOGY_MEAN

Name: Geopotential Height, Climatology - Mean

Definition:
The mean altitude of points in the atmosphere expressed into the geopotential of those altitudes.

AC: GHCM

Recommended Data Type: SE_INT32

Possible Enumerators: None

Recommended Maximum Value: +99999

Recommended Minimum Value: -400

Recommended Significant Digits: 5

Recommended Tolerance: 1

Units: EDCS_UNITS_GEOPOTENTIAL_METERS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_GEOPOTENTIAL_HEIGHT_CLIMATOLOGY_STD_DEV

Name: Geopotential Height, Climatology - Standard Deviation

Definition:
The quantity of the standard deviation of geopotential heights.

AC: GHCS

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 2000.0

Recommended Minimum Value: 0.0

Recommended Significant Digits: 5

Recommended Tolerance: .1

Units: EDCS_UNITS_GEOPOTENTIAL_METERS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_GEOPOTENTIAL_HEIGHT

Name: Geopotential Height (Altitude)

Definition:
The altitude of a point in the atmosphere expressed into the geopotential at that altitude.

AC: GHE_

Recommended Data Type: SE_INT32

Possible Enumerators: None

Recommended Maximum Value: +99999

Recommended Minimum Value: -400

Recommended Significant Digits: 5

Recommended Tolerance: 1

Units: EDCS_UNITS_GEOPOTENTIAL_METERS

Source: JMCDM inputs 8-11-98


Label: EDCS_AC_GT_OR_EQLT_CONTOUR_INTERVAL

Name: Greater Than or Equal To / Less Than Contour Interval

Definition:
Indicates whether the predominant height or depth is greater than (or equal to), or less than the contour interval.

AC: GLI_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GLI__UNKNOWN Unknown
1 SE_PROP_VAL_GLI__GT_OR_EQ_TO_CONTOUR_INTERVAL Greater than or Equal to Contour Interval
2 SE_PROP_VAL_GLI__LT_CONTOUR_INTERVAL Less than Contour Interval
997 SE_PROP_VAL_GLI__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GLI__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GLI__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0a


Label: EDCS_AC_GEOMAGNETIC_FIELD_DECLINATION_ANGLE

Name: Geomagnetic Field, Declination Angle

Definition:
The declination angle between magnetic north and geodetic north.

AC: GMD_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +5400

Recommended Minimum Value: -5400

Recommended Significant Digits: 5

Recommended Tolerance: .1

Units: EDCS_UNITS_MINUTE_ARC

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_DECLINATION_ANGLE_MEAN

Name: Geomagnetic Field, Declination Angle - Mean

Definition:
The mean declination angle between magnetic north and geodetic north, typically averaged over one hour.

AC: GMDM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: +5400

Recommended Minimum Value: -5400

Recommended Significant Digits: 5

Recommended Tolerance: .1

Units: EDCS_UNITS_MINUTE_ARC

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_EAST_COMPONENT

Name: Geomagnetic Field, East Component

Definition:
The strength of the geodetic east vector component of the geomagnetic field.

AC: GME_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_EAST_COMPONENT_MEAN

Name: Geomagnetic Field, East Component - Mean

Definition:
The mean strength of the geodetic east vector component of the geomagnetic field, typically averaged over one hour.

AC: GMEM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_FULL_COMPONENT

Name: Geomagnetic Field, Full Component

Definition:
The strength of the full vector component of the geomagnetic field (vector sum of east, north, and vertical components). (See also GEOMAGNETIC_FIELD_EAST_COMPONENT , GEOMAGNETIC_FIELD_NORTH_COMPONENT and GEOMAGNETIC_FIELD_VERTICAL_COMPONENT .)

AC: GMF_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_FULL_COMPONENT_MEAN

Name: Geomagnetic Field, Full Component - Mean

Definition:
The mean strength of the full vector component of the geomagnetic field (vector sum of all components), typically averaged over one hour. (See also GEOMAGNETIC_FIELD_EAST_COMPONENT_MEAN , GEOMAGNETIC_FIELD_NORTH_COMPONENT_MEAN and GEOMAGNETIC_FIELD_VERTICAL_COMPONENT_MEAN .)

AC: GMFM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_HORIZONTAL_COMPONENT

Name: Geomagnetic Field, Horizontal Component

Definition:
The strength of the horizontal vector component of the geomagnetic field (vector sum of east and north components). (See also GEOMAGNETIC_FIELD_EAST_COMPONENT and GEOMAGNETIC_FIELD_NORTH_COMPONENT .)

AC: GMH_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_HORIZONTAL_COMPONENT_MEAN

Name: Geomagnetic Field, Horizontal Component - Mean

Definition:
The mean strength of the horizontal vector component of geomagnetic field (vector sum of east and north components), typically averaged over one hour. (See also GEOMAGNETIC_FIELD_EAST_COMPONENT_MEAN and GEOMAGNETIC_FIELD_NORTH_COMPONENT_MEAN .)

AC: GMHM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_NORTH_COMPONENT

Name: Geomagnetic Field, North Component

Definition:
The strength of the geodetic north vector component of the geomagnetic field.

AC: GMN_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_NORTH_COMPONENT_MEAN

Name: Geomagnetic Field, North Component - Mean

Definition:
The mean strength of the geodetic north vector component of the geomagnetic field, typically averaged over one hour.

AC: GMNM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_VERTICAL_COMPONENT

Name: Geomagnetic Field, Vertical Component

Definition:
The strength of the vertical vector component of the geomagnetic field.

AC: GMV_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GEOMAGNETIC_FIELD_VERTICAL_COMPONENT_MEAN

Name: Geomagnetic Field, Vertical Component - Mean

Definition:
The mean strength of the vertical vector component of geomagnetic field, typically averaged over one hour.

AC: GMVM

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 100,000

Recommended Minimum Value: 0

Recommended Significant Digits: 6

Recommended Tolerance: 1

Units: EDCS_UNITS_NANOTESLA

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GATE_NAUTICAL_CLASSIFICATION

Name: Gate (Nautical) Classification

Definition:
Tabulation of various types of nautical gates.

AC: GNC_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GNC__UNDEFINED Undefined
1 SE_PROP_VAL_GNC__GATE_IN_GENERAL Gate in general
2 SE_PROP_VAL_GNC__TIDAL_GATE_FLOOD_BARRAGE Tidal gate (flood barrage)
3 SE_PROP_VAL_GNC__CAISSON Caisson
4 SE_PROP_VAL_GNC__LOCK_GATE Lock gate
5 SE_PROP_VAL_GNC__DYKE_GATE Dyke Gate
997 SE_PROP_VAL_GNC__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GNC__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GNC__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GEOMORPHIC_DEPTH

Name: Geomorphic Depth

Definition:
Depth of the object below average surface level as determined by a corresponding digital elevation matrix. If not obtainable, the average depth will be used.

AC: GPD_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: Not Applicable

Recommended Tolerance: 1

Units: EDCS_UNITS_METER

Source: DIGEST Edition 2.0a


Label: EDCS_AC_GRID_DIAGONALIZATION

Name: Grid Diagonalization

Definition:
The direction along which a grid cell formed by four adjacent data values is divided into two triangular facets.

AC: GRD_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GRD__DATA_MISSING_OR_UNKNOWN Data Missing / Unknown
1 SE_PROP_VAL_GRD__LOWERLEFT_UPPERRIGHT_DIAG Lower Left to/from Upper Right
2 SE_PROP_VAL_GRD__UPPERLEFT_LOWERRIGHT_DIAG Upper Left to/from Lower Right
997 SE_PROP_VAL_GRD__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GRD__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded

Units: EDCS_UNITS_ENUMERATION

Source: Associate inputs to support EDCS Implementation Release 2.5


Label: EDCS_AC_GROUP_OF_SIGNALS_DEFINITION

Name: Group of Signals Definition

Definition:
Encodes the number of signals, the combination of signals or the Morse character(s) within one full period of sequence.

AC: GRP_

Recommended Data Type: SE_LEX_STRING

Possible Enumerators: None

Recommended Maximum Value: Not Applicable

Recommended Minimum Value: Not Applicable

Recommended Significant Digits: 256

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_UNITS_NOT_APPLICABLE

Source: DIGEST Edition 2.0


Label: EDCS_AC_GLIDE_SLOPE_ANGLE

Name: Glide Slope Angle

Definition:
The angle at which an aircraft should properly descend to a touchdown point.

AC: GSA_

Recommended Data Type: SE_FLOAT32

Possible Enumerators: None

Recommended Maximum Value: 4.99

Recommended Minimum Value: 0

Recommended Significant Digits: Not Applicable

Recommended Tolerance: Not Applicable

Units: EDCS_UNITS_DEGREE_ARC

Source: DIGEST Edition 2.1


Label: EDCS_AC_GROUND_SLOPE_CATEGORY

Name: Ground Slope Category

Definition:
Range indicating the slope of ground within delineated area of the object.

AC: GSC_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GSC__UNKNOWN Unknown
1 SE_PROP_VAL_GSC__0_TO_gt45_CULTURALLY_OR_NATURALLY_DISSECTED_LAND (0 to > 45) Culturally or Naturally Dissected Land
2 SE_PROP_VAL_GSC__le3 <= 3
3 SE_PROP_VAL_GSC__gt3_AND_le10 > 3 and <= 10
4 SE_PROP_VAL_GSC__gt10_AND_le20 > 10 and <= 20
5 SE_PROP_VAL_GSC__gt20_AND_le30 > 20 and <= 30
6 SE_PROP_VAL_GSC__gt30_AND_le45 > 30 and <= 45
7 SE_PROP_VAL_GSC__gt45 > 45
8 SE_PROP_VAL_GSC__gt10_AND_le15 > 10 and <= 15
9 SE_PROP_VAL_GSC__gt15_AND_le20 > 15 and <= 20
10 SE_PROP_VAL_GSC__gt45_AND_le60 > 45 and <= 60
11 SE_PROP_VAL_GSC__gt60 > 60
12 SE_PROP_VAL_GSC__gt60_AND_le85 > 60 and <= 85
13 SE_PROP_VAL_GSC__gt85 > 85
997 SE_PROP_VAL_GSC__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GSC__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GSC__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GATE_TYPE_CATEGORY

Name: Gate Type Category

Definition:
The classification of the type of barrier or gate.

AC: GTC_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GTC__UNKNOWN Unknown
1 SE_PROP_VAL_GTC__TOLLGATE Tollgate
2 SE_PROP_VAL_GTC__CROSSING Crossing
997 SE_PROP_VAL_GTC__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GTC__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GTC__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GUYED_OR_UNGUYED_CATEGORY

Name: Guyed or Unguyed Category

Definition:
Presence of support wires.

AC: GUG_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GUG__UNKNOWN Unknown
1 SE_PROP_VAL_GUG__GUYED Guyed
2 SE_PROP_VAL_GUG__UNGUYED Unguyed
997 SE_PROP_VAL_GUG__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GUG__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GUG__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GAP_WIDTH_RANGE_1

Name: Gap Width Range, Primary

Definition:
Predominant horizontal gap width range (primary), measured between the top of the first accessible break in slope above mean water level on each bank.

AC: GW1_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GW1__UNKNOWN Unknown
1 SE_PROP_VAL_GW1__le3 <= 3
2 SE_PROP_VAL_GW1__gt3_AND_le18 > 3 and <= 18
3 SE_PROP_VAL_GW1__gt18_AND_le25 > 18 and <= 25
4 SE_PROP_VAL_GW1__gt25_AND_le50 > 25 and <= 50
5 SE_PROP_VAL_GW1__gt50_AND_le75 > 50 and <= 75
6 SE_PROP_VAL_GW1__gt75_AND_le100 > 75 and <= 100
7 SE_PROP_VAL_GW1__gt100_AND_le142 > 100 and <= 142
8 SE_PROP_VAL_GW1__gt142 > 142
9 SE_PROP_VAL_GW1__NA NA
997 SE_PROP_VAL_GW1__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GW1__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GAP_WIDTH_RANGE_2

Name: Gap Width Range, Secondary

Definition:
Predominant horizontal gap width range (secondary), measured between the top of the first accessible break in slope above mean water level on each bank.

AC: GW2_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GW2__UNKNOWN Unknown
1 SE_PROP_VAL_GW2__gt18_AND_le142 > 18 and <= 142
2 SE_PROP_VAL_GW2__gt142_AND_le1000 > 142 and <= 1000
3 SE_PROP_VAL_GW2__gt1000 > 1000
4 SE_PROP_VAL_GW2__NA NA
997 SE_PROP_VAL_GW2__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GW2__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0


Label: EDCS_AC_GAP_WIDTH_3

Name: Gap Width (Greater Precision)

Definition:
Predominant horizontal gap width range with greater precision, measured between the top of the first accessible break in slope above mean water level on each bank.

AC: GW3_

Recommended Data Type: EDCS_AC_ENUM_VALUE

Possible Enumerators:

0 SE_PROP_VAL_GW3__UNKNOWN Unknown
1 SE_PROP_VAL_GW3__le1pt5 <= 1.5 Meters
2 SE_PROP_VAL_GW3__gt1pt5_AND_le3pt0 > 1.5 and <= 3.0 Meters
3 SE_PROP_VAL_GW3__gt3pt0_AND_le18pt0 > 3.0 and <= 18.0 Meters
4 SE_PROP_VAL_GW3__gt18pt0_AND_le25pt0 > 18.0 and <= 25.0 Meters
5 SE_PROP_VAL_GW3__gt25pt0_AND_le30pt0 > 25.0 and <= 30.0 Meters
6 SE_PROP_VAL_GW3__gt30pt0_AND_le35pt0 > 30.0 and <= 35.0 Meters
7 SE_PROP_VAL_GW3__gt35pt0_AND_le40pt0 > 35.0 and <= 40.0 Meters
8 SE_PROP_VAL_GW3__gt40pt0_AND_le45pt0 > 40.0 and <= 45.0 Meters
9 SE_PROP_VAL_GW3__gt45pt0_AND_le50pt0 > 45.0 and <= 50.0 Meters
10 SE_PROP_VAL_GW3__gt50pt0_AND_le75pt0 > 50.0 and <= 75.0 Meters
11 SE_PROP_VAL_GW3__gt75pt0_AND_le100pt0 > 75.0 and <= 100.0 Meters
12 SE_PROP_VAL_GW3__gt100pt0_AND_le142pt0 > 100.0 and <= 142.0 Meters
13 SE_PROP_VAL_GW3__gt142pt0 > 142.0 Meters
997 SE_PROP_VAL_GW3__DATA_WITHHELD Data Withheld
998 SE_PROP_VAL_GW3__NOT_APPLICABLE_OR_POINT_EXCLUDED Not Applicable / Point Excluded
999 SE_PROP_VAL_GW3__OTHER Other

Units: EDCS_UNITS_ENUMERATION

Source: DIGEST Edition 2.0a


Prev:AC_F.htm Next:AC_H.htm Up:Index